Description
Ellis ER19-23 Emperor Trefoil Cable Cleats
Cable Cleat Maximum Short Circuit Test Level 195/149kA – Cleat Spacing 300/600mm
The Ellis ER19-23 Emperor Cable Cleats are manufactured by Ellis Patents from corrosion-resistant 316L stainless steel for LV (Low Voltage), MV (Medium Voltage), and HV (High Voltage) power cable circuits. The robust design is suitable for clamping industrial LV-HV power cables, rigorously tested to meet the stringent IEC 61914 standards.
Key Features of ER19-23 Emperor Trefoil Cable Cleats
- Material: Corrosion-resistant 316L stainless steel
- Application: Suitable for LV, MV, and HV power cable circuits
- Cable Diameter: Secures trefoil power cables between 19-23mm overall cable diameter
- Design: Features captive closure fixings for fast and reliable installation
- Sizes: Available in a range of sizes for single, trefoil, and bundled cable installations
Detailed Specifications of ER19-23 Emperor Trefoil Cable Cleats
- Cable Cleat Diameter Min: 19mm
- Cable Cleat Diameter Max: 23mm
- Dimensions:
- Width: 96mm
- Height: 83mm
- Depth: 54mm
- P: 25mm
- Base Holes: 2 x M10 + 1 x M12
- Weight: 425g
Trefoil Cable Cleat Selection Table
Emperor Cable Cleat Part Number | Trefoil Cable Range | Dimensions | Weight (g) | |||||
Min Dia (mm) | Max Dia (mm) | W (Max) (mm) | H (Max) (mm) | D (mm) | P (mm) | Base Holes | ||
ER19-23 | 19 | 23 | 96 | 83 | 54 | 25 | 2 x M10 + 1 x M12 | 425 |
Installation Instructions for Ellis ER19-23 Emperor Trefoil Cable Cleats
- Securing the Cleat: Bolt the cleat to the support structure using the two outer M10 or the central M12 fixing positions provided.
- Cable Installation: Position the cables within the cleat. For larger cables in the cleat's range, adjust the spacing as necessary to accommodate the cable diameter.
- Closing the Cleat: Remove the flange nut and carefully bend the two edges of the cleat around the cables until they are parallel. Ensure the screw aligns with the adjacent hole and then replace the flange nut.
- Final Tightening: Tighten the flange nut to secure the cleat. Warning: Avoid over-tightening the cable cleat. The liner should make firm contact with the cable, but should not compress or deform the cable.
Additional Resources for Ellis ER19-23 Emperor Trefoil Cable Cleats
- Ellis ER19-23 Emperor Trefoil Cleats – Data Sheet (PDF)
- Ellis Patents Emperor Cable Cleats – Installation Instructions (PDF)
Ellis Emperor Short Circuit Test Video
Ellis ER19-23 Emperor Trefoil Cable Cleats Calculator
This calculator is designed to provide correctly specified cleat spacings with respect to short circuit conditions. The calculator considers; cable formation, cable size, short circuit current and the installation environment. Further detail on the calculator and other factors that effect cable spacing is provided below the calculator.
Access Cleat Calculator here
Enquire About Ellis ER19-23 Emperor Trefoil Cable Cleats
For more information or information on how toplace an order, please contact us at sales@nasco-corp.com
Specifications
Please see the all the sizes of the complete line of Emperor cleats